4.1 FT82 SERVOPACKs with Analog Voltage/Pulse Train References
Parameter
No.
Pn514
4-26
Name
Output Signal Selec-
2
tions 4
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
/PM (Preventative Maintenance Output) Signal Allocation
0
Disabled (the above signal output is not used).
1
Output the signal from the CN1-25 or CN1-26 output terminal.
2
Output the signal from the CN1-27 or CN1-28 output terminal.
n.
X
3
Output the signal from the CN1-29 or CN1-30 output terminal.
4
Output the signal from the CN1-37 output terminal.
5
Output the signal from the CN1-38 output terminal.
6
Output the signal from the CN1-39 output terminal.
n.X
Reserved parameter (Do not change.)
Setting
Setting
Default
Range
Unit
Setting
0000h to
–
0000h
0666h
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
All
Setup
restart
Reference
Continued on next page.
Refer-
ence
–
*1