4.2 FT82 SERVOPACK with MECHATROLINK-II Communications References

4.2
FT82 SERVOPACK with MECHATROLINK-II Communications References
The following table lists the parameters.
Note: Do not change the following parameters from their default settings.
Parameter
No.
Pn000
Pn001
4-32
• Reserved parameters
• Parameters not given in this manual
• Parameters that are not valid for the Servomotor that you are using, as given in the parameter table
Name
Basic Function Selec-
2
tions 0
Rotation Direction Selection

n.
X
0
1

n.
X
Reserved parameter (Do not change.)

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Application Function
2
Selections 1
Motor Stopping Method for Servo OFF and Group 1 Alarms
0

n.
X
1
2
Overtravel Stopping Method
0
1

n.
X
2
3
4
Main Circuit Power Supply AC/DC Input Selection
0

n.
X
1

n.X
Reserved parameter (Do not change.)
Setting
Setting
Default
Range
Unit
Setting
0000h to
10B1h
Use CCW as the forward direction.
Use CW as the forward direction. (Reverse Rotation Mode)
0000h to
1142h
Stop the motor by applying the dynamic brake.
Stop the motor by the applying dynamic brake and then release
the dynamic brake.
Coast the motor to a stop without the dynamic brake.
Apply the dynamic brake or coast the motor to a stop (use the
stopping method set in Pn001 = n.X).
Decelerate the motor to a stop using the torque set in Pn406 as
the maximum torque and then servo-lock the motor.
Decelerate the motor to a stop using the torque set in Pn406 as
the maximum torque and then let the motor coast.
Decelerate the motor to a stop using the deceleration time set in
Pn30A and then servo-lock the motor.
Decelerate the motor to a stop using the deceleration time set in
Pn30A and then let the motor coast.
Input AC power as the main circuit power supply using the L1, L2,
and L3 terminals (do not use shared converter).
Input DC power as the main circuit power supply using the B1/
and
2 terminals or the B1 and
converter or the shared converter).
Applicable
When
Motors
Enabled
After
0000h
All
restart
After
0000h
All
restart
2 terminals (use an external
Continued on next page.
Classi-
Refer-
fication
ence
Setup
Reference
*1
Setup
Reference
*1
Reference
*1
Reference
*1