Parameter
Name
No.
Input Signal Selections
2
4
/ZCLAMP (Zero Clamping Input) Signal Allocation

n.
X
Pn50D
/INHIBIT (Reference Pulse Inhibit Input) Signal Allocation

n.
X
/G-SEL (Gain Selection Input) Signal Allocation

n.
X

n.X
Reserved parameter (Do not change.)
4.1 FT82 SERVOPACKs with Analog Voltage/Pulse Train References
Setting
Setting
Range
Unit
0000h to
FFFFh
0
Active when CN1-40 input signal is ON (closed).
1
Active when CN1-41 input signal is ON (closed).
2
Active when CN1-42 input signal is ON (closed).
3
Active when CN1-43 input signal is ON (closed).
4
Active when CN1-44 input signal is ON (closed).
5
Active when CN1-45 input signal is ON (closed).
6
Active when CN1-46 input signal is ON (closed).
7
The signal is always active.
8
The signal is always inactive.
9
Active when CN1-40 input signal is OFF (open).
A
Active when CN1-41 input signal is OFF (open).
B
Active when CN1-42 input signal is OFF (open).
C
Active when CN1-43 input signal is OFF (open).
D
Active when CN1-44 input signal is OFF (open).
E
Active when CN1-45 input signal is OFF (open).
F
Active when CN1-46 input signal is OFF (open).
The allocations are the same as the /ZCLAMP
0 to F
(Zero Clamping Input) signal allocations.
The allocations are the same as the /ZCLAMP
0 to F
(Zero Clamping Input) signal allocations.
Continued from previous page.
Default
Applicable
When
Setting
Motors
Enabled
After
8888h
restart
Applicable
Motors
All
Applicable
Motors
All
Applicable
Motors
All
Continued on next page.
Classi-
Refer-
fication
ence
Setup
Reference
*1
Reference
*1
Reference
*1
4
4-23