Ft82 Servopack With Mechatrolink-Ii Communications References - YASKAWA SGM7D-30F Product Manual

E-7-series ac servo drive e-7s servopack with ft/ex specification for application with special motor, sgm7d motor
Table of Contents

Advertisement

Parameter
Name
No.
Application Function
2
Selections 7
Analog Monitor 2 Signal Selection

n.
XX
Pn007
11 to 5F

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Application Function
2
Selections 8
Low Battery Voltage Alarm/Warning Selection

n.
X
Function Selection for Undervoltage
Pn008

n.
X
Warning Detection Selection

n.
X

n.X
Reserved parameter (Do not change.)

4.2 FT82 SERVOPACK with MECHATROLINK-II Communications References

Setting
Setting
Range
Unit
0000h to
105Fh
00
Motor speed (1 V/1,000 min
01
Speed reference (1 V/1,000 min
02
Torque reference (1 V/100% rated torque)
03
Position deviation (0.05 V/reference unit)
04
Position amplifier deviation (after electronic gear) (0.05 V/encoder pulse unit)
05
Position reference speed (1 V/1,000 min
06
Reserved setting (Do not use.)
07
Load-motor position deviation (0.01 V/reference unit)
Positioning completion (positioning completed: 5 V, positioning not com-
08
pleted: 0 V)
09
Speed feedforward (1 V/1,000 min
0A
Torque feedforward (1 V/100% rated torque)
0B
Active gain (1st gain: 1 V, 2nd gain: 2 V)
Completion of position reference distribution (completed: 5 V, not com-
0C
pleted: 0 V)
0D
External encoder speed (1 V/1,000 min
0E
Reserved setting (Do not use.)
0F
Reserved setting (Do not use.)
10
Main circuit DC voltage
Reserved settings (Do not use.)
0000h to
7121h
0
Output alarm (A.830) for low battery voltage.
1
Output warning (A.930) for low battery voltage.
0
Do not detect undervoltage.
1
Detect undervoltage warning and limit torque at host controller.
Detect undervoltage warning and limit torque with Pn424 and
2
Pn425 (i.e., only in SERVOPACK).
0
Detect warnings.
1
Do not detect warnings except for A.971.
Continued from previous page.
Default
Applicable
When
Setting
Motors
Enabled
Immedi-
0000h
All
ately
-1
)
-1
)
-1
)
-1
)
-1
: value at the motor shaft)
After
4000h
Rotary
restart
Continued on next page.
Classi-
Refer-
fication
ence
Setup
*1
Setup
Reference
*1
Reference
*1
Reference
*1
4
4-35

Hide quick links: