4.2 FT82 SERVOPACK with MECHATROLINK-II Communications References
Parameter
No.
Pn50A
4-48
Name
Input Signal Selections
2
1

n.
X
Reserved parameter (Do not change.)

n.
X
Reserved parameter (Do not change.)

n.
X
Reserved parameter (Do not change.)
P-OT (Forward Drive Prohibit) Signal Allocation
0
Enable forward drive when CN1-13 input signal is ON (closed).
1
Enable forward drive when CN1-7 input signal is ON (closed).
2
Enable forward drive when CN1-8 input signal is ON (closed).
3
Enable forward drive when CN1-9 input signal is ON (closed).
4
Enable forward drive when CN1-10 input signal is ON (closed).
5
Enable forward drive when CN1-11 input signal is ON (closed).
6
Enable forward drive when CN1-12 input signal is ON (closed).

n.X
7
Set the signal to always prohibit forward drive.
8
Set the signal to always enable forward drive.
9
Enable forward drive when CN1-13 input signal is OFF (open).
A
Enable forward drive when CN1-7 input signal is OFF (open).
B
Enable forward drive when CN1-8 input signal is OFF (open).
C
Enable forward drive when CN1-9 input signal is OFF (open).
D
Enable forward drive when CN1-10 input signal is OFF (open).
E
Enable forward drive when CN1-11 input signal is OFF (open).
F
Enable forward drive when CN1-12 input signal is OFF (open).
Setting
Setting
Default
Range
Unit
Setting
0000h to
1881h
FFF2h
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
All
Setup
restart
Reference
Continued on next page.
Refer-
ence
*1