YASKAWA SGM7D-30F Product Manual page 492

E-7-series ac servo drive e-7s servopack with ft/ex specification for application with special motor, sgm7d motor
Table of Contents

Advertisement

Parameter
Name
No.
Input Signal Selections
2
10
/MODE 0/1 (Mode Switch Input) Signal Allocation

n.
X
/START-STOP (Program Table Operation Start-Stop Input) Signal Alloca-
tion
Pn630

n.
X
/HOME (Origin Return Input) Signal Allocation

n.
X
0 to F
/PGMRES (Program Table Operation Reset Input) Signal Allocation

n.X
0 to F
4.5 FT83 SERVOPACKs with Analog Voltage/Pulse Train References
Setting
Setting
Range
Unit
0000h to
FFFFh
0
Mode 0 is used when CN1-40 input signal is ON (closed).
1
Mode 0 is used when CN1-41 input signal is ON (closed).
2
Mode 0 is used when CN1-42 input signal is ON (closed).
3
Mode 0 is used when CN1-43 input signal is ON (closed).
4
Mode 0 is used when CN1-44 input signal is ON (closed).
5
Mode 0 is used when CN1-45 input signal is ON (closed).
6
Mode 0 is used when CN1-46 input signal is ON (closed).
7
The signal always specifies mode 0.
8
The signal always specifies mode 1.
9
Mode 0 is used when CN1-40 input signal is OFF (open).
A
Mode 0 is used when CN1-41 input signal is OFF (open).
B
Mode 0 is used when CN1-42 input signal is OFF (open).
C
Mode 0 is used when CN1-43 input signal is OFF (open).
D
Mode 0 is used when CN1-44 input signal is OFF (open).
E
Mode 0 is used when CN1-45 input signal is OFF (open).
F
Mode 0 is used when CN1-46 input signal is OFF (open).
0
Active when CN1-40 input signal is ON (closed).
1
Active when CN1-41 input signal is ON (closed).
2
Active when CN1-42 input signal is ON (closed).
3
Active when CN1-43 input signal is ON (closed).
4
Active when CN1-44 input signal is ON (closed).
5
Active when CN1-45 input signal is ON (closed).
6
Active when CN1-46 input signal is ON (closed).
7
The signal is always active.
8
The signal is always inactive.
9
Active when CN1-40 input signal is OFF (open).
A
Active when CN1-41 input signal is OFF (open).
B
Active when CN1-42 input signal is OFF (open).
C
Active when CN1-43 input signal is OFF (open).
D
Active when CN1-44 input signal is OFF (open).
E
Active when CN1-45 input signal is OFF (open).
F
Active when CN1-46 input signal is OFF (open).
The settings are the same as for /START-STOP (Program Table
Operation Start-Stop Input) Signal Allocation.
The settings are the same as for /START-STOP (Program Table
Operation Start-Stop Input) Signal Allocation.
Continued from previous page.
Default
Applicable
When
Setting
Motors
Enabled
After
6221h
All
restart
Continued on next page.
Classi-
Refer-
fication
ence
Setup
Reference
*1
Reference
*1
Reference
*1
Reference
*1
4
4-167

Hide quick links: