Function Application Restrictions - YASKAWA SGM7D-30F Product Manual

E-7-series ac servo drive e-7s servopack with ft/ex specification for application with special motor, sgm7d motor
Table of Contents

Advertisement

1.4 Functions

1.4.2 Function Application Restrictions

1.4.2

Function Application Restrictions

The following functional restrictions apply when you use the FT82/FT83 SERVOPACKs.
Setting the Linear Encoder Pitch
Writing Linear Servomotor Param-
eters
Selecting the Phase Sequence for
a Linear Servomotor
Polarity Sensor Setting
Polarity Detection
Speed Ripple Compensation
Tuning-less Function
1-10
Function
Cannot be used.
Cannot be used.
Cannot be used.
Cannot be used.
Cannot be used.
Cannot be used.
Do not change the following default setting: Pn423 = n.0.
Cannot be used if the load moment of inertia ratio is 10 or greater.
Restriction