4.5 FT83 SERVOPACKs with Analog Voltage/Pulse Train References
Parameter
No.
Pn50B
4-158
Name
Input Signal Selections
2
2
N-OT (Reverse Drive Prohibit) Signal Allocation
0
Enable reverse drive when CN1-40 input signal is ON (closed).
1
Enable reverse drive when CN1-41 input signal is ON (closed).
2
Enable reverse drive when CN1-42 input signal is ON (closed).
3
Enable reverse drive when CN1-43 input signal is ON (closed).
4
Enable reverse drive when CN1-44 input signal is ON (closed).
5
Enable reverse drive when CN1-45 input signal is ON (closed).
6
Enable reverse drive when CN1-46 input signal is ON (closed).

n.
X
7
Set the signal to always prohibit reverse drive.
8
Set the signal to always enable reverse drive.
9
Enable reverse drive when CN1-40 input signal is OFF (open).
A
Enable reverse drive when CN1-41 input signal is OFF (open).
B
Enable reverse drive when CN1-42 input signal is OFF (open).
C
Enable reverse drive when CN1-43 input signal is OFF (open).
D
Enable reverse drive when CN1-44 input signal is OFF (open).
E
Enable reverse drive when CN1-45 input signal is OFF (open).
F
Enable reverse drive when CN1-46 input signal is OFF (open).
/ALM-RST (Alarm Reset) Signal Allocation
Active on signal edge when CN1-40 input signal changes from
0
OFF (open) to ON (closed).
Active on signal edge when CN1-41 input signal changes from
1
OFF (open) to ON (closed).
Active on signal edge when CN1-42 input signal changes from
2
OFF (open) to ON (closed).
Active on signal edge when CN1-43 input signal changes from
3
OFF (open) to ON (closed).
Active on signal edge when CN1-44 input signal changes from
4
OFF (open) to ON (closed).
Active on signal edge when CN1-45 input signal changes from
5
OFF (open) to ON (closed).
Active on signal edge when CN1-46 input signal changes from
6
OFF (open) to ON (closed).

n.
X
7
Reserved setting (Do not use.)
8
The signal is always inactive.
Active on signal edge when CN1-40 input signal changes from ON
9
(closed) to OFF (open).
Active on signal edge when CN1-41 input signal changes from ON
A
(closed) to OFF (open).
Active on signal edge when CN1-42 input signal changes from ON
B
(closed) to OFF (open).
Active on signal edge when CN1-43 input signal changes from ON
C
(closed) to OFF (open).
Active on signal edge when CN1-44 input signal changes from ON
D
(closed) to OFF (open).
Active on signal edge when CN1-45 input signal changes from ON
E
(closed) to OFF (open).
Active on signal edge when CN1-46 input signal changes from ON
F
(closed) to OFF (open).
/P-CL (Forward External Torque Limit Input) Signal Allocation

n.
X
0 to F
The allocations are the same as the /S-ON (Servo ON) signal allocations.
/N-CL (Reverse External Torque Limit Input) Signal Allocation

n.X
0 to F
The allocations are the same as the /S-ON (Servo ON) signal allocations.
Setting
Setting
Default
Range
Unit
Setting
0000h to
8868h
FFFFh
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
All
Setup
restart
Reference
Reference
Reference
Reference
Continued on next page.
Refer-
ence
*1
*1
*1
*1