Parameter
Name
No.
Output Signal Inverse
2
Settings
Output Signal Inversion for CN1-1 and CN1-2 Terminals

n.
X
Output Signal Inversion for CN1-23 and CN1-24 Terminals
Pn512

n.
X
Output Signal Inversion for CN1-25 and CN1-26 Terminals

n.
X

n.X
Reserved parameter (Do not change.)
Output Signal Selec-
2
tions 4

n.
X
Reserved parameter (Do not change.)

n.
X
Reserved parameter (Do not change.)
/PM (Preventative Maintenance Output) Signal Allocation
Pn514

n.
X

n.X
Reserved parameter (Do not change.)
4.3 FT82 SERVOPACK with MECHATROLINK-III Communications References
Setting
Setting
Range
Unit
0000h to
1111h
0
The signal is not inverted.
1
The signal is inverted.
0
The signal is not inverted.
1
The signal is inverted.
0
The signal is not inverted.
1
The signal is inverted.
0000h to
0666h
0
Disabled (the above signal output is not used).
1
Output the signal from the CN1-1 or CN1-2 output terminal.
2
Output the signal from the CN1-23 or CN1-24 output terminal.
3
Output the signal from the CN1-25 or CN1-26 output terminal.
4 to 6
Reserved setting (Do not use.)
4.3.1 List of Servo Parameters
Continued from previous page.
Default
Applicable
When
Setting
Motors
Enabled
After
0000h
All
restart
After
0000h
All
restart
Continued on next page.
Classi-
Refer-
fication
ence
Setup
*1
Setup
Reference
*1
4
4-89