3.1.3 Troubleshooting Alarms
Alarm Number:
Alarm Name
A.bF1:
System Alarm 1
A.bF2:
System Alarm 2
A.bF3:
System Alarm 3
A.bF4:
System Alarm 4
A.bF5:
System Alarm 5
A.bF6:
System Alarm 6
A.bF7:
System Alarm 7
A.bF8:
System Alarm 8
3-24
Possible Cause
A failure occurred in
the SERVOPACK.
A failure occurred in
the SERVOPACK.
A failure occurred in
the SERVOPACK.
A failure occurred in
the SERVOPACK.
A failure occurred in
the SERVOPACK.
A failure occurred in
the SERVOPACK.
A failure occurred in
the SERVOPACK.
A failure occurred in
the SERVOPACK.
Confirmation
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Continued from previous page.
Correction
Reference
Continued on next page.