YASKAWA SGM7D-30F Product Manual page 379

E-7-series ac servo drive e-7s servopack with ft/ex specification for application with special motor, sgm7d motor
Table of Contents

Advertisement

4.2 FT82 SERVOPACK with MECHATROLINK-II Communications References
Parameter
No.
Pn52C
Pn530
Pn531
Pn533
Pn534
Pn535
Pn536
Pn550
Pn551
Pn552
Pn553
Pn55A
Pn560
Pn561
Pn600
4-54
Name
Base Current Derating
2
at Motor Overload
Detection
Program Jogging-
2
Related Selections
Program Jogging Operation Pattern
(Waiting time in Pn535 → Forward by travel distance in Pn531) × Number of
0
movements in Pn536
(Waiting time in Pn535 → Reverse by travel distance in Pn531) × Number of
1
movements in Pn536
(Waiting time in Pn535 → Forward by travel distance in Pn531) × Number of
movements in Pn536
2
(Waiting time in Pn535 → Reverse by travel distance in Pn531) × Number of
movements in Pn536

n.
X
(Waiting time in Pn535 → Reverse by travel distance in Pn531) × Number of
movements in Pn536
3
(Waiting time in Pn535 → Forward by travel distance in Pn531) × Number of
movements in Pn536
(Waiting time in Pn535 → Forward by travel distance in Pn531 → Waiting time
in Pn535 → Reverse by travel distance in Pn531) × Number of movements in
4
Pn536
(Waiting time in Pn535 → Reverse by travel distance in Pn531 → Waiting time
in Pn535 → Forward by travel distance in Pn531) × Number of movements in
5
Pn536

n.
X
Reserved parameter (Do not change.)

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Program Jogging Travel
4
Distance
Program Jogging Move-
2
ment Speed
Program Jogging Accel-
2
eration/Deceleration
Time
Program Jogging Wait-
2
ing Time
Program Jogging Num-
2
ber of Movements
Analog Monitor 1 Offset
2
Voltage
Analog Monitor 2 Offset
2
Voltage
Analog Monitor 1 Mag-
2
nification
Analog Monitor 2 Mag-
2
nification
Power Consumption
2
Monitor Unit Time
Residual Vibration
2
Detection Width
Overshoot Detection
2
Level
Regenerative Resistor
2
*5
Capacity
Setting
Setting
Default
Range
Unit
Setting
10 to 100
1%
100
0000h to
0000h
0005h
1 refer-
1 to
ence
32768
1,073,741,824
unit
Rotary:
-1
1 min
Direct
1 to 10,000
500
Drive:
0.1
-1
min
2 to 10,000
1 ms
100
0 to 10,000
1 ms
100
0 to 1,000
Times
1
-10,000 to
0.1 V
0
10,000
-10,000 to
0.1 V
0
10,000
-10,000 to
× 0.01
100
10,000
-10,000 to
× 0.01
100
10,000
1 to 1,440
1 min
1
1 to 3,000
0.1%
400
0 to 100
1%
100
Depends on
10 W
0
*6
model.
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
All
Setup
restart
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
Rotary
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Continued on next page.
Refer-
ence
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents