4.5 FT83 SERVOPACKs with Analog Voltage/Pulse Train References
Parameter
No.
Pn50D
Pn50E
4-160
Name
Input Signal Selections
2
4
/ZCLAMP (Zero Clamping Input) Signal Allocation
0
Active when CN1-40 input signal is ON (closed).
1
Active when CN1-41 input signal is ON (closed).
2
Active when CN1-42 input signal is ON (closed).
3
Active when CN1-43 input signal is ON (closed).
4
Active when CN1-44 input signal is ON (closed).
5
Active when CN1-45 input signal is ON (closed).
6
Active when CN1-46 input signal is ON (closed).
n.
X
7
The signal is always active.
8
The signal is always inactive.
9
Active when CN1-40 input signal is OFF (open).
A
Active when CN1-41 input signal is OFF (open).
B
Active when CN1-42 input signal is OFF (open).
C
Active when CN1-43 input signal is OFF (open).
D
Active when CN1-44 input signal is OFF (open).
E
Active when CN1-45 input signal is OFF (open).
F
Active when CN1-46 input signal is OFF (open).
/INHIBIT (Reference Pulse Inhibit Input) Signal Allocation
n.
X
The allocations are the same as the /ZCLAMP
0 to F
(Zero Clamping Input) signal allocations.
/G-SEL (Gain Selection Input) Signal Allocation
n.
X
The allocations are the same as the /ZCLAMP
0 to F
(Zero Clamping Input) signal allocations.
n.X
Reserved parameter (Do not change.)
Output Signal Selec-
2
tions 1
/COIN (Positioning Completion Output) Signal Allocation
0
Disabled (the above signal output is not used).
1
Output the signal from the CN1-25 or CN1-26 output terminal.
2
Output the signal from the CN1-27 or CN1-28 output terminal.
n.
X
3
Output the signal from the CN1-29 or CN1-30 output terminal.
4
Output the signal from the CN1-37 output terminal.
5
Output the signal from the CN1-38 output terminal.
6
Output the signal from the CN1-39 output terminal.
/V-CMP (Speed Coincidence Detection Output) Signal Allocation
n.
X
The allocations are the same as the /COIN (Positioning Comple-
0 to 6
tion) signal allocations.
/TGON (Rotation Detection Output) Signal Allocation
n.
X
The allocations are the same as the /COIN (Positioning Comple-
0 to 6
tion) signal allocations.
/S-RDY (Servo Ready) Signal Allocation
n.X
The allocations are the same as the /COIN (Positioning Comple-
0 to 6
tion) signal allocations.
Setting
Setting
Default
Range
Unit
Setting
0000h to
–
0888h
FFFFh
0000h to
–
2011h
6666h
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
–
Setup
restart
Applicable
Reference
Motors
All
Applicable
Reference
Motors
All
Applicable
Reference
Motors
All
After
All
Setup
restart
Reference
Reference
Reference
Reference
Continued on next page.
Refer-
ence
–
*1
*1
*1
–
*1
*1
*1
*1