10.4.2

Condition data setting examples

The following shows setting examples for "condition data".
(1) Setting the device ON/OFF as a condition
[Condition] Device "XC" (= Axis 1 BUSY signal) is OFF
[Da.15]
Condition target
01H: Device X
(2) Setting the numeric value stored in the "buffer memory" as a condition
[Condition]
The value stored in buffer memory addresses "800, 801" (= "[Md.20] Current feed value") is "1000" or larger.
[Da.15]
Condition target
04H: Buffer memory (2
words)
(3) Designating the axis and positioning data No. to be simultaneously started in
"simultaneous start"
[Condition] Simultaneously starting "axis 2 positioning data No.3"
[Da.15]
Condition target
05H: Positioning data No.
*1
The setting value of start axis (the axis which executes positioning start) should be "0000H".
472
[Da.16]
Condition operator
08H: DEV=OFF
[Da.16]
Condition operator
04H: **P1
[Da.16]
Condition operator
20H: Axis 2 designation
[Da.17]
Address
Parameter 1
[Da.17]
Address
Parameter 1
800
[Da.17]
Address
Parameter 1
High-order 16 bits "0003H"
[Da.18]
[Da.19]
Parameter 2
0CH
[Da.18]
[Da.19]
Parameter 2
1000
[Da.18]
[Da.19]
Parameter 2
*1
*1