(36)[Cd.38] Teaching data selection
Item
• This data item specifies the teaching result write destination.
Setting details
• Data are cleared to "0" when the teaching ends.
■Set with a decimal.
Setting
value
Setting value
Default value
0
Axis 1: 1548
Storage buffer memory
Axis 2: 1648
address
Axis 3: 1748
Axis 4: 1848
(37)[Cd.39] Teaching positioning data No.
Item
• This data item specifies data to be produced by teaching.
• If a value (1 to 600) is set, a teaching operation is done.
Setting details
• The value is cleared to "0" when the LD75 is initialized, when a teaching operation completes, and when an illegal value (601 or
higher) is entered.
■Set with a decimal.
Setting value
Setting value
Default value
0
Axis 1: 1549
Storage buffer memory
Axis 2: 1649
address
Axis 3: 1749
Axis 4: 1849
K
Teaching data selection
0: Takes the current feed value as a positioning
address.
1: Takes the current feed value as an arc data.
K
CHAPTER 5 DATA USED FOR POSITIONING CONTROL
Description
Description
Teaching
positioning
data No.
1 to 600
5