9.2.25

LEND

The LEND is used to return the operation to the top of the repeat (LOOP to LEND) loop.
(1) Operation
When the repeat cycle designated by the LOOP becomes 0, the loop is terminated, and the next positioning data
No. processing is started. (The operation pattern, if set to "Positioning complete", will be ignored.)
When the operation is stopped after the repeat operation is executed by designated cycles, the dummy
positioning data (for example, incremental positioning without movement amount) is set next to LEND.
The operation for the case when Positioning complete (00) is set to LOOP or LEND is shown below.
Positioning data No.
1
2
3
4
5
6
(2) Positioning data setting example
The following table shows the setting examples when "LEND" is set in positioning data No. 8 of axis 1.
Setting item
[Da.1]
Operation pattern
[Da.2]
Control system
[Da.3]
Acceleration time No.
[Da.4]
Deceleration time No.
[Da.5]
Axis to be interpolated
Axis 1
positioning
Positioning
[Da.6]
data No. 8
address/movement amount
[Da.7]
Arc address
[Da.8]
Command speed
[Da.9]
Dwell time
[Da.10]
M code
Refer to  Page 152, Section 5.3 for information on the setting details.
(3) Restrictions
• Ignore the "LEND" before the "LOOP" is executed.
Operation pattern
Control system
Continuous control
Positioning complete
Continuous path control
Continuous control
Positioning complete
Positioning complete
Setting
example
LEND
CHAPTER 9 MAJOR POSITIONING CONTROL
Condition
ABS2
LOOP
Number of loop cycles: 2
ABS2
ABS2
LEND
ABS2
Setting details
Setting not required. (Setting value will be ignored.)
Set the LEND.
Setting not required. (Setting value will be ignored.)
Setting not required. (Setting value will be ignored.)
Setting not required. (Setting value will be ignored.)
Setting not required. (Setting value will be ignored.)
Setting not required. (Setting value will be ignored.)
Setting not required. (Setting value will be ignored.)
Setting not required. (Setting value will be ignored.)
Setting not required. (Setting value will be ignored.)
9
Operation
Executed in the order of
the positioning data No. 1
 2  3  4  5  2 
3  4  5  6.
(The operation patterns of
the positioning data Nos.
2 and 5 are ignored.)
455