Mitsubishi Electric MELSEC-L LD75P User Manual page 359

Positioning module
Hide thumbs Also See for MELSEC-L LD75P:
Table of Contents

Advertisement

• To specify the rotation direction in degrees for each positioning data when multiple positioning data is
processed continuously within one positioning operation in continuous positioning control or continuous path
control, use "[Da.28] ABS direction in degrees".
• To set the same rotation direction for all positioning data, setting "[Cd.40] ABS direction in degrees" enables
batch specification of the rotation direction for each positioning data. To use "[Cd.40] ABS direction in
degrees", set "0" in "[Da.28] ABS direction in degrees". When a value other than "0" is set, the setting of
"[Da.28] ABS direction in degrees" becomes valid. The set value in "[Cd.40] ABS direction in degrees"
becomes valid only when the positioning control is started. In the continuous positioning control or
continuous path control, the operation is continued with the setting made at a start if the setting is changed
during the operation.
Name
Set the ABS moving direction in position control when
"degree" is selected as the unit.
[Cd.40] ABS
0: Shortcut (direction setting ignored)
direction in degrees
1: ABS clockwise
2: ABS counterclockwise
Set "ABS direction in degrees" for each positioning data.
0: Use the set value in "[Cd.40] ABS direction in degrees".
[Da.28] ABS
1: ABS clockwise
direction in degrees
2: ABS counterclockwise
3: Shortcut (direction setting ignored)
*1
N indicates the offset address of each positioning data.
N = ((Positioning data No.)  1)  10
Function
CHAPTER 9 MAJOR POSITIONING CONTROL
Buffer memory address
Axis 1
Axis 2
Axis 3
1550
1650
1750
*1
*1
2003 + N
8003 + N
14003 + N
(b2 to b3)
(b2 to b3)
(b2 to b3)
Initial value
Axis 4
1850
0
*1
*1
20003 + N
0
(b2 to b3)
357
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-l ld75d

Table of Contents