Mitsubishi Electric MELSEC-L LD75P User Manual page 610

Positioning module
Hide thumbs Also See for MELSEC-L LD75P:
Table of Contents

Advertisement

(3) Setting method
To use the "stop command processing for deceleration stop function", set the following control data in a program.
The set data are made valid as soon as they are written to the buffer memory. The PLC READY signal [Y0] is
irrelevant.
Setting item
Stop command
processing for
[Cd.42]
deceleration stop
selection
Refer to  Page 211, Section 5.7 for the information on detail settings.
608
Setting
Setting details
value
Set the stop command processing for
deceleration stop function.
0: Deceleration curve re-processing
1: Deceleration curve continuation
Buffer memory address
1907