Zp.pinit - Mitsubishi Electric MELSEC-L LD75P User Manual

Positioning module
Hide thumbs Also See for MELSEC-L LD75P:
Table of Contents

Advertisement

14.7

ZP.PINIT

This dedicated instruction is used to initialize the setting data of the LD75.
Setting data
Internal device
Bit
Word
(S)
(D)
[Instruction symbol]
ZP.PINIT
(1) Setting data
*1
Setting data
LD75 head I/O number
"Un"
(00 to FE: High-order two digits of I/O number expressed in three digits)
(S)
Head number of a device in which control data is stored
Head number of a bit device which turns ON the operation by one scan at the time of
(D)
completion of the instruction.
If the instruction is completed abnormally, ((D)+1) will also be turned ON.
*1
The file register of each of the local device and the program cannot be used as a device for setting data.
*2
The data on the setting side is as follows.
• User: Data before the execution of dedicated instructions is stored by user.
• System: Data after the execution of dedicated instruction is stored by CPU module.
(2) Control data
Device
Item
(S)+0
System area
(S)+1
Complete status
*1
The data on the setting side is as follows.
• User: Data before the execution of dedicated instructions is stored by user.
• System: Data after the execution of dedicated instruction is stored by CPU module.
*2
Refer to  Page 650, Section 15.5 for error codes at abnormal completion.
Link direct device
J\
File register
Bit
[Execution condition]
Setting details
Setting data
The state at the time of completion is stored.
0: Normal completion
Other than 0: Abnormal completion (error code)
CHAPTER 14 DEDICATED INSTRUCTIONS
Usable device
Intelligent function
Index register
module
U\G
Word
ZP.PINIT
Setting side
Setting range
*2
Constant
Others
Zn
K, H
"Un"
(S)
(D)
*2
Data type
User
BIN 16 bits
Device name
System
Bit
*1
Setting side
System
637
14

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-l ld75d

Table of Contents