Mitsubishi Electric MELSEC-L LD75P User Manual page 231

Positioning module
Hide thumbs Also See for MELSEC-L LD75P:
Table of Contents

Advertisement

(27)[Cd.29] Target position change request flag
Item
Setting details
Requests the target position change during a positioning operation.
■Set with a decimal.
Setting
value
Setting value
Default value
0
Axis 1: 1538
Storage buffer memory
Axis 2: 1638
address
Axis 3: 1738
Axis 4: 1838
(28)[Cd.30] Simultaneous starting axis start data No. (axis 1 start data No.)
Item
• Use these data items to specify a start data No. for each axis that has to start simultaneously.
Setting details
• Set "0" to any axis that should not start simultaneously.
■Set with a decimal.
Setting
value
Setting value
Default value
0
Axis 1: 1540
Storage buffer memory
Axis 2: 1640
address
Axis 3: 1740
Axis 4: 1840
1
K
Target position change request flag
1: Requests a target position change
The LD75 resets the value to "0" automatically
when the new target position value has been written.
(This indicates the completion of target position change request.)
K
CHAPTER 5 DATA USED FOR POSITIONING CONTROL
Description
Description
Cd.30 to Cd.33
Simultaneous starting
axis start data No.:
1 to 600
5