(2) Connecting and disconnecting cables
(a) When a bar solderless terminal is used
• Connection
A flathead screwdriver is not required. Directly insert a cable with a bar solderless terminal into the slot so
that the crimp side faces to the external device connector (faces to the left when viewed from the insertion
direction).
• Disconnection
Open the slot using a flathead screwdriver and disconnect the cable from the slot. When two cables are
connected, disconnect the cable of the upper slot first.
(b) When a bar solderless terminal is not used
• Connection
Open the slot using a flathead screwdriver and insert a cable to the slot. When two cables are to be used,
connect a cable to the lower slot first.
• Disconnection
Open the slot using a flathead screwdriver and disconnect the cable from the slot. When two cables are
connected, disconnect the cable of the upper slot first.
(3) Operating the open/close lever
The following shows how to operate the open/close lever of the differential driver common terminal.
For operation, use a commercially available small flathead screwdriver.
Push the driver onto the hollow
of the lever (orange) straight.
Lever
Insertion slot
Flathead
screwdriver
When a bar solderless terminal is not used, strip the cable jacket 8 to 11mm. If the length is too short, a secure connection
may not be obtained.
90
The lever goes down and the
insertion slot opens.
Flathead
screwdriver
Lever
Insertion slot