(10)[Da.9] Dwell time (JUMP destination positioning data No.)
Set the "dwell time" or "positioning data No." corresponding to the "[Da.2] Control system".
• When a method other than "JUMP instruction " is set for "[Da.2] Control system": Set the "dwell time".
• When "JUMP instruction " is set for "[Da.2] Control system": Set the "positioning data No." for the JUMP
destination.
When the "dwell time" is set, the setting details of the "dwell time" will be as follows according to "[Da.1]
Operation pattern".
1) When " Da.1 Operation pattern" in "00: Positioning complete"
Set the time from when the positioning ends to when the
"positioning complete signal" turns ON as the "dwell time".
2) When " Da.1 Operation pattern" is "01: Continuous positioning control"
Set the time from when positioning control ends to when
the next positioning control starts as the "dwell time".
3) When " Da.1 Operation pattern" is "11: Continuous path control"
The setting value is irrelevant to the control.
(The "dwell time" is 0ms.)
(a) Setting range
[Da.2] setting value
JUMP instruction: 82H
Other than JUMP instruction
168
Positioning complete signal
Setting item
Positioning data No.
Dwell time
V
Positioning control
OFF
V
Positioning control
V
Positioning control
Value set with GX Works2
1 to 600
0 to 65535 (ms)
t
ON
Da.9
Dwell time
Next positioning
control
t
Da.9
Dwell time
Next positioning control
t
No dwell time (0ms)
Value set with program
1 to 600
0 to 65535 (ms)