Mitsubishi Electric MELSEC-L LD75P User Manual page 586

Positioning module
Hide thumbs Also See for MELSEC-L LD75P:
Table of Contents

Advertisement

(4) Setting method
(a) To specify the M code ON signal output timing for each positioning data
Use "[Da.27] M code ON signal output timing". The following shows the settings to use "[Da.27] M code ON
signal output timing".
• Set the M code No. in the positioning data "[Da.10] M code".
• Set the timing to output the M code ON signal [X4, X5, X6, X7] in the positioning data "[Da.27] M code ON
signal output timing".
(b) To set the same M code ON signal output timing for all positioning data
Setting "[Pr.18] M code ON signal output timing" enables batch specification of M code ON signal output timing
for each positioning data. Set 0 in "[Da.27] M code ON signal output timing" when using "[Pr.18] M code ON
signal output timing". When a value other than 0 is set, "[Da.27] M code ON signal output timing" will be valid.
(The setting in "[Pr.18] M code ON signal output timing" becomes valid on the rising edge (OFF to ON) of PLC
READY signal [Y0].)
The following shows the settings to use "[Pr.18] M code ON signal output timing".
• Set the M code No. in the positioning data "[Da.10] M code".
• Set "0: Use the set value in "[Pr.18] M code ON signal output timing"." (initial value) in the positioning data
"[Da.27] M code ON signal output timing".
• Set the timing to output the M code ON signal [X4, X5, X6, X7] in the detailed parameter "[Pr.18] M code ON
signal output timing".
Setting item
M code ON signal
[Pr.18]
output timing
M code ON signal
[Da.27]
output timing
*1
N indicates the offset address of each positioning data.
N = ((Positioning data No.) - 1)  10
Refer to  Page 118, Section 5.2 for the information on detail settings.
584
Setting
Setting details
value
Set the timing to output the M code ON signal.
0: WITH mode
1: AFTER mode
Set the M code ON signal output timing for each
positioning data.
0: Use the set value in "[Pr.18] M code ON
signal output timing".
1: WITH mode
2: AFTER mode
Buffer memory address
Axis 1
Axis 2
Axis 3
27
177
327
*1
*1
2003 + N
8003 + N
14003 + N
(b4 to b6)
(b4 to b6)
(b4 to b6)
Axis 4
477
*1
*1
20003 + N
(b4 to b6)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-l ld75d

Table of Contents