Mitsubishi Electric MELSEC-L LD75P User Manual page 209

Positioning module
Hide thumbs Also See for MELSEC-L LD75P:
Table of Contents

Advertisement

(21)[Md.40] In speed change processing flag
Item
• The speed change process flag turns ON when the speed is changed during positioning control.
Storage details
• After the speed change process is completed or when deceleration starts with the stop signal during the speed change process,
the in speed change process flag turns OFF.
■Monitoring is carried out with a decimal display.
Monitor
Reading the monitor
value
value
Default value
0
Axis 1: 831
Storage buffer memory
Axis 2: 931
address
Axis 3: 1031
Axis 4: 1131
(22)[Md.41] Special start repetition counter
Item
• This area stores the remaining number of repetitions during "repetitions" specific to special starting.
• The count is decremented by one (-1) at the loop end.
Storage details
• The control comes out of the loop when the count reaches "0".
• This area stores "0" within an infinite loop.
■Monitoring is carried out with a decimal display.
Reading the monitor
Monitor value
value
Default value
0
Axis 1: 832
Storage buffer memory
Axis 2: 932
address
Axis 3: 1032
Axis 4: 1132
(23)[Md.42] Control system repetition counter
Item
• This area stores the remaining number of repetitions during "repetitions" specific to control system.
Storage details
• The count is decremented by one (-1) at the loop start.
• The loop is terminated with the positioning data of the control method "LEND", after the counter becomes "0".
■Monitoring is carried out with a hexadecimal display.
Reading the monitor
Monitor value
value
Default value
0000H
Axis 1: 833
Storage buffer memory
Axis 2: 933
address
Axis 3: 1033
Axis 4: 1133
CHAPTER 5 DATA USED FOR POSITIONING CONTROL
Description
Storage value
0: Not in speed change (OFF)
1: In speed change (ON)
Description
Storage value
0 to 255
Description
Storage value
0 to FFFF