Operation Patterns Of Major Positioning Controls - Mitsubishi Electric MELSEC-L LD75P User Manual

Positioning module
Hide thumbs Also See for MELSEC-L LD75P:
Table of Contents

Advertisement

9.1.2

Operation patterns of major positioning controls

In "major positioning control" (high-level positioning control), "[Da.1] Operation pattern" can be set to designate
whether to continue executing positioning data after the started positioning data. The "operation pattern" includes the
following 3 types ((1) to (3)).
The following shows examples of operation patterns when "1-axis linear control (ABS linear 1)" is set in positioning
data No. 1 to No. 6 of axis 1.
< Operation example when "1-axis linear positioning" is set in the positioning data of axis 1 >
Positioning data No.1
No.2
No.3
No.4
No.5
No.6
Speed
Da. 1 Operation pattern
b
11
a
NO.1
0
A
(Positioning data)
(One motor is driven, and positioning is carried out to an addresses designated in one direction.)
The BUSY signal [XC, XD, XE, XF] turns ON even when position control of movement amount 0 is executed. However, since
the ON time is short, the ON status may not be detected in the program.
342
• Positioning complete
• Positioning continue
(Setting details)
Positioning to address [A] at command speed [a]
Positioning to address [B] at command speed [b]
Positioning to address [C] at command speed [a]
Positioning to address [D] at command speed [b]
Positioning to address [E] at command speed [a]
Positioning to address [F] at command speed [a]
11
01
Speed is changed
without stopping
No.2
No.3
B
C
For
1-axis linear control
(1) Independent positioning control
(operation pattern: 00)
(2) Continuous positioning control
(operation pattern: 01)
(3) Continuous path control
(operation pattern: 11)
Operation pattern = 11: Continuous path control
Operation pattern = 11: Continuous path control
Operation pattern = 01:
Operation pattern = 01:
Operation pattern = 00: Independent positioning control
Operation pattern = 11: Continuous path control
01
The machine stops, and
then continues the next
positioning.
No.4
D
(Direction in which axis 1 addresses increase)
Continuous positioning control
Continuous positioning control
(Positioning complete)
Control stop
00
Positioning is terminated
No.5
Address
E
F
No.1 Start
Time