Mitsubishi Electric MELSEC-L LD75P User Manual page 578

Positioning module
Hide thumbs Also See for MELSEC-L LD75P:
Table of Contents

Advertisement

(7) Setting method
To use the "step function", write the data shown in the following table to the LD75 using the program. Refer to
 Page 574, Section 12.7.1 (4) for the timing of the settings.
The set details are validated when written to the LD75.
Setting item
[Cd.34]
Step mode
[Cd.35]
Step valid flag
Step start
[Cd.36]
information
Refer to  Page 211, Section 5.7 for the information on detail settings.
576
Setting value
Set "0: Deceleration unit step" or "1: Data No. unit
step".
1
Set "1: Carry out step operation".
Set "1: Step continue", depending on the stop status.
Setting details
Buffer memory address
Axis 1
Axis 2
Axis 3
1544
1644
1744
1545
1645
1745
1546
1646
1746
Axis 4
1844
1845
1846

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-l ld75d