(15)[Cd.17] JOG speed
Item
Setting details
Use this data item to set the JOG speed. ( Page 221, Section 5.7.2 (15) (a))
■Set with a decimal.
Actual value
Setting value
Setting value
(Decimal)
Example: When the " Cd. 17 JOG
Default value
0
Axis 1: 1518, 1519
Storage buffer memory
Axis 2: 1618, 1619
address
Axis 3: 1718, 1719
Axis 4: 1818, 1819
(a) Setting range
[Pr.1] Unit setting
0: mm
1: inch
2: degree
3: pulse
Cd.17 JOG speed
Conversion into an integer value
n
10
R
speed" is set as "20000.00mm
/min", the buffer memory
stores "2000000".
0 to 2000000000 (10
0 to 2000000000 (10
0 to 2000000000 (10
0 to 4000000 (pulse/s)
CHAPTER 5 DATA USED FOR POSITIONING CONTROL
Description
Unit conversion table ( Cd.17 )
n
Unit
mm/min
-2
inch/min
-3
degree/min
-3
pulse/s
0
Setting range
-2
mm/min)
-3
inch/min)
-3
degree/min)
5