Classification
Error
of errors
code
506
Large arc error deviation
Positioning
operation
507
Software stroke limit+
656
Error name
Operation status at error occurrence
■Description
When an arc or helix is interpolated by the
designation of the center point, a difference
between a radius of start point-center point and a
radius of end point-center point exceeds the
parameter "Allowable circular interpolation error
width".
■Operation status at error occurrence
At start: The system will not operate.
During operation: The system will stop immediately.
■Description
• Positioning is carried out at a position beyond the
software stroke limit upper limit.
• The positioning address and new current value
exceed the software stroke limit upper limit.
• The sub point exceeds the software stroke limit
upper limit in the circular interpolation or helical
interpolation with sub point designation.
■Operation status at error occurrence
At operation start: The system will not operate.
At current value changing analysis: The current
value is not changed.
During operation:
• When the positioning address exceeds the
software stroke limit range and the control is
switched to the one for the out-of-range data
during a position control (including the position
control in speed-position switching control and
position-speed switching control), the system will
stop immediately.
• When the current feed value or machine feed
value during speed control (including speed-
position and position-speed switching control) or
manual control exceeds the software stroke limit
range, the system will stop with the setting
(deceleration stop only) of the detailed parameter
2 Sudden stop selection (stop group 3).
Action/Related buffer memory address/Set
range (Setting with program)
■Action
• Correct the center point address (arc address).
• Correct the end point address (positioning
address).
■Buffer memory address
Page 152, Section 5.3
■Setting range
Positioning address/movement amount
• ABS
Unit [mm] [pulse] [inch]: -2147483648 to
2147483647
Unit [degree]: 0 to 35999999
• INC
(When the software stroke limit is valid)
Unit [degree]: -35999999 to 35999999
Unit [mm] [pulse] [inch]: -2147483648 to
2147483647
(When the software stroke limit is invalid)
-2147483648 to 2147483647
• Speed-position switching
INC mode: 0 to 2147483647
ABS mode: 0 to 35999999
• Position-speed switching
0 to 2147483647
Arc address: -2147483648 to 2147483647
■Action
At operation start:
• Bring the current feed value into the software
stroke limit using the manual control operation.
( Page 479, CHAPTER 11)
• Correct the positioning address. (Also check
the arc address in the circular interpolation or
helical interpolation with sub point designation.)
Current value changing: Set the new current
value within the software stroke limit range. (
Page 447, Section 9.2.21)
During operation: Correct the positioning address.
(For the positioning and arc addresses, refer to
 Page 159, Section 5.3 (7) and Page 164,
Section 5.3 (8).)
■Buffer memory address
• New current value
Axis 1: 1506, 1507
Axis 2: 1606, 1607
Axis 3: 1706, 1707
Axis 4: 1806, 1807
• Software stroke limit upper limit
Axis 1: 18, 19
Axis 2: 168, 169
Axis 3: 318, 319
Axis 4: 468, 469
■Setting range
New current value, software stroke limit upper
limit value
• [mm] [inch] [pulse]: -2147483648 to
2147483647
• [degree]: 0 to 35999999