List Of Control Data; System Control Data - Mitsubishi Electric MELSEC-L LD75P User Manual

Positioning module
Hide thumbs Also See for MELSEC-L LD75P:
Table of Contents

Advertisement

5.7

List of Control Data

5.7.1

System control data

(1) [Cd.1] Flash ROM write request
Item
Setting details
Requests writing of data from the buffer memory to the flash ROM. (Parameters, positioning data, and block start data)
■Set with a decimal.
Setting
value
Setting value
Default value
0
Storage buffer memory
address
1900
(Common to axes 1 to 4)
(2) [Cd.2] Parameter initialization request
Item
Requests initialization of setting data.
Initialization  Resetting of setting data to default values
Note) After completing the initialization of setting data, reset the CPU module or reboot the power for the programmable controller.
Setting details
Initialized setting data
• Parameters ([Pr.1] to [Pr.57], [Pr.150])
• Positioning data (No.1 to No.600)
• Block start data (No.7000 to 7004)
■Set with a decimal.
Setting
value
Setting value
Default value
0
Storage buffer memory
address
1901
(Common to axes 1 to 4)
K 1
Flash ROM write request
1: Requests write access
to flash ROM.
The LD75 resets the value to "0" automatically
when the write access completes.
(This indicates the completion of write operation.)
K 1
Parameter initialization request
1: Requests parameter
initialization.
The LD75 resets the value to "0" automatically
when the initialization completes.
(This indicates the completion of parameter)
CHAPTER 5 DATA USED FOR POSITIONING CONTROL