• If the "[Pr.49] OPR dwell time" elapses before the stop at the stopper, the workpiece will stop at that position,
and that position will be regarded as the OP. At this time, an error will not occur.
Machine OPR start
(Positioning start signal)
[Y10,Y11,Y12,Y13]
OPR request flag
Md.31
Status : b3
OPR complete flag
Md.31
Status : b4
Deviation counter clear output
Md.26
Axis operation status
Movement amount
Md.34
after near-point dog
ON
Md.20
Current feed value
Machine feed value
Md.21
Md.35
Torque limit stored
value
• The near-point dog must be turned ON until it presses against the stopper. If any range that the near-point is
turned OFF exists until it presses against the stopper, executing the machine OPR from the area leads it to
be pressed against the stopper at ORR speed.
• Machine OPR started while the near-point dog is ON will start at the "[Pr.47] Creep speed".
• When a machine OPR is stopped with the stop signal, perform a machine OPR again. If the restart
command is turned ON after a stop with the stop signal, an error "OPR restart not possible" (error code: 209)
occurs.
326
V
OPR speed
Pr.46
Torque limit
Near-point dog
OFF
ON
OFF
ON
OFF
OFF
In OPR
Standing by
0
Inconsistent
Value the machine moved is stored
Inconsistent
Torque limit setting value
Inconsistent
Creep speed
Pr.47
Valid torque
limit range
ON
Dwell time
measurement
ON
Pr.55
Deviation counter clear
signal output time
Standing by
OP address
OPR torque limit value
Stopper
t
Time out of dwell time