Item
Value set with GX Works2
The setting range differs depending on the "[Pr.1] Unit setting".
[Pr.53] OP shift amount
( Page 150, Section 5.2.6 (5) (a))
[Pr.54] OPR torque
1 to 300 (%)
limit value
[Pr.55] Deviation
counter clear signal
1 to 65535 (ms)
output time
[Pr.56] Speed
0: OPR speed
designation during OP
1: Creep speed
shift
[Pr.57] Dwell time
0 to 65535 (ms)
during OPR retry
*1
0 to 32767: Set as a decimal
32768 to 65535: Convert into hexadecimal and set
(5) [Pr.53] OP shift amount
Set the amount to shift (move) from the position stopped at with machine OPR.
The OP shift function is used to compensate the OP position stopped at with machine OPR.
If there is a physical limit to the OP position, due to the relation of the near-point dog installation position, use this
function to compensate the OP to an optimum position.
When "
shift amount" is negative
(a) Setting range
[Pr.1] setting value
0: mm
1: inch
2: degree
3: pulse
150
Setting value, setting range
Value set with program
1 to 65535 (ms)
0 to 65535 (ms)
OPR direction
Pr.44
Shift point
Start point
OP
Pr.53
Near-point dog signal
Zero signal
Value set with GX Works2 (unit)
-214748364.8 to 214748364.7 (m)
-21474.83648 to 21474.83647 (inch)
-21474.83648 to 21474.83647 (degree)
-2147483648 to 2147483647 (pulse)
Default value
0
1 to 300 (%)
300
*1
11
0
0
1
*1
0
When "
shift amount" is positive
Shift point
Shift after deviation
counter clear is canceled
-2147483648 to 2147483647 (10
-2147483648 to 2147483647 (10
-2147483648 to 2147483647 (10
-2147483648 to 2147483647 (pulse)
Setting value buffer memory
address
Axis 1
Axis 2
Axis 3
84
234
384
85
235
385
86
236
386
87
237
387
88
238
388
89
239
389
OP
Pr.53
Value set with program (unit)
-1
m)
-5
inch)
-5
degree)
Axis 4
534
535
536
537
538
539

Advertisement