Mitsubishi Electric MELSEC-L LD75P User Manual page 5

Positioning module
Hide thumbs Also See for MELSEC-L LD75P:
Table of Contents

Advertisement

[Wiring Precautions]
● Use applicable solderless terminals.
Failure to do so may result in malfunction or damage to the module or cables.
● Tighten the connector screws within the specified torque range.
Undertightening can cause short circuit, fire, or malfunction.
Overtightening can damage the screw and/or module, resulting in drop, short circuit, fire, or
malfunction.
● Connectors for external devices must be crimped with the tool specified by the manufacturer or must
be correctly soldered. Incomplete connections may cause short circuit, fire, or malfunction.
● Place the cables in a duct or clamp them.
If not, dangling cable may swing or inadvertently be pulled, resulting in damage to the module or
cables or malfunction due to poor contact.
● When disconnecting the cable from the module, do not pull the cable by the cable part.
For the cable with connector, hold the connector part of the cable.
Pulling the cable connected to the module may result in malfunction or damage to the module or
cable.
● Prevent foreign matter such as dust or wire chips from entering the module. Such foreign matter can
cause a fire, failure, or malfunction.
● A protective film is attached to the top of the module to prevent foreign matter, such as wire chips,
from entering the module during wiring. Do not remove the film during wiring. Remove it for heat
dissipation before system operation.
CAUTION
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-l ld75d

Table of Contents