(29)[Md.48] Deceleration start flag
Item
• "1" is stored when the constant speed status or acceleration status switches to the deceleration status during position control
Storage details
whose operation pattern is "Positioning complete".
• "0" is stored at the next operation start or manual pulse generator operation enable.
■Monitoring is carried out with a decimal display.
Monitor value
Reading the monitor
value
Default value
0
Axis 1: 899
Storage buffer memory
Axis 2: 999
address
Axis 3: 1099
Axis 4: 1199
210
Description
Storage value
0: Status other than below
1: Status from deceleration
start to next operation
start or manual pulse
generator operation enable