10 HIGH-LEVEL POSITIONING CONTROL

10.4.2 Condition data setting examples

The following shows setting examples for "condition data".
(1) Setting the device ON/OFF as a condition
[Condition] Device "X0" (=QD75 READY) is OFF
Da.15
Condition target
01
: Device X
H
(2) Setting the numeric value stored in the "buffer memory" as a
condition
[Condition]
The value stored in buffer memory addresses "800, 801" (= "
feed value") is "1000" or larger.
Da.15
Condition target
04
: Buffer memory
H
(2 words)
(3) Designating the axis and positioning data No. to be simultaneously
started in "simultaneous start"
[Condition]
Simultaneously starting "axis 2 positioning data No.3".
Da.15
Condition target
05
: Positioning
H
data No.
Da.16
Condition
Address
operator
08
: DEV=OFF
H
Da.16
Condition
Address
operator
≥ P1
04
:
H
Da.16
Da.17
Condition
Address
operator
20
: Axis 2
H
designation
10 - 19
Da.17
Da.18
Parameter 1
0
Da.17
Da.18
Parameter 1
800
1000
Da.18
Parameter 1
High-order 16
bits "0003
"
H
MELSEC-Q
Da.19
Parameter 2
Md.20
Current
Da.19
Parameter 2
Da.19
Parameter 2