(11)[Cd.13] Positioning operation speed override
Item
• To use the positioning operation speed override function, use this data item to specify an "override" value.
• For details on "override", refer to  Page 550, Section 12.5.2.
Setting details
• If the speed becomes lower than the minimum unit due to override 1% or others, it is raised to the minimum unit. At this time, the
warning "Less than minimum speed" (warning code: 110) will occur.
■Set with a decimal.
Setting value
Setting value
Default value
100
Axis 1: 1513
Storage buffer memory
Axis 2: 1613
address
Axis 3: 1713
Axis 4: 1813
(12)[Cd.14] New speed value
Item
• When changing the speed, use this data item to specify a new speed. ( Page 219, Section 5.7.2 (12) (a))
Setting details
• The operation halts if you specify "0".
■Set with a decimal.
Actual value
Setting value
Setting value
Default value
0
Axis 1: 1514, 1515
Storage buffer memory
Axis 2: 1614, 1615
address
Axis 3: 1714, 1715
Axis 4: 1814, 1815
218
K
Cd.14 New speed value
Conversion into an integer value
10
R
(Decimal)
Example: When the " Cd. 14 New speed
value" is set as "20000.00mm
/min", the buffer memory
stores "2000000".
Description
Override value (%)
Description
Unit conversion table ( Cd.14 )
n
n
-2
-3
-3
0
1 to 300
Unit
mm/min
inch/min
degree/min
pulse/s