(3) [Cd.41] Deceleration start flag valid
Item
Storage details
Set whether "[Md.48] Deceleration start flag" is made valid or invalid.
■Set with a decimal.
Setting
value
Setting value
Default value
0
Storage buffer memory
address
1905
(Common to axes 1 to 4)
(4) [Cd.42] Stop command processing for deceleration stop selection
Item
Set the stop command processing for deceleration stop function (deceleration curve re-processing/deceleration curve
Storage details
continuation).
■Set with a decimal.
Setting
value
Setting value
Default value
0
Storage buffer memory
address
1907
(Common to axes 1 to 4)
(5) [Cd.43] Output timing selection of near pass control
Item
Select the timing to output the difference (l) between the actual and the set positioning end addresses in continuous path control,
Storage details
in which the difference (l) is output during the execution of the next positioning data.
■Set with a decimal.
Setting value
Default value
0
Storage buffer memory
address
1934
(Common to axes 1 to 4)
212
K
Deceleration start flag valid
0: Deceleration start flag invalid
1: Deceleration start flag valid
K
Stop command processing for deceleration stop selection
0: Deceleration curve re-processing
1: Deceleration curve continuation
Description
Description
Description