(3) [Cd.41] Deceleration start flag valid
Item
Storage details
Set whether "[Md.48] Deceleration start flag" is made valid or invalid.
■Set with a decimal.
Setting
value
Setting value
Default value
0
Storage buffer memory
address
1905
(Common to axes 1 to 4)
(4) [Cd.42] Stop command processing for deceleration stop selection
Item
Set the stop command processing for deceleration stop function (deceleration curve re-processing/deceleration curve
Storage details
continuation).
■Set with a decimal.
Setting
value
Setting value
Default value
0
Storage buffer memory
address
1907
(Common to axes 1 to 4)
(5) [Cd.43] Output timing selection of near pass control
Item
Select the timing to output the difference (l) between the actual and the set positioning end addresses in continuous path control,
Storage details
in which the difference (l) is output during the execution of the next positioning data.
■Set with a decimal.
Setting value
Default value
0
Storage buffer memory
address
1934
(Common to axes 1 to 4)
212
K
Deceleration start flag valid
0: Deceleration start flag invalid
1: Deceleration start flag valid
K
Stop command processing for deceleration stop selection
0: Deceleration curve re-processing
1: Deceleration curve continuation
Description