Mitsubishi Electric MELSEC-L LD75P User Manual page 613

Positioning module
Hide thumbs Also See for MELSEC-L LD75P:
Table of Contents

Advertisement

(4) Parameter initialization method
• Parameter initialization is carried out using the dedicated instruction "ZP.PINIT".
(Refer to  Page 619, CHAPTER 14 for details.)
• Parameter initialization can also be carried out by the writing of the data shown in the table below to the
buffer memory using the TO instruction /intelligent function device.
The initialization of the parameter is executed at the time point the data is written to the LD75 buffer
memory.
Setting item
Parameter initialization
[Cd.2]
request
Refer to  Page 211, Section 5.7 for the information on detail settings.
When the initialization is complete, "0" will be set in "[Cd.2] Parameter initialization request" by the LD75
automatically.
Setting
Setting details
value
1
Set "1" (parameter initialization request).
CHAPTER 13 COMMON FUNCTIONS
Buffer memory address
Axis 1
Axis 2
Axis 3
Axis 4
1901
611
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-l ld75d

Table of Contents