Mitsubishi Electric MELSEC-L LD75P User Manual page 420

Positioning module
Hide thumbs Also See for MELSEC-L LD75P:
Table of Contents

Advertisement

(4) Positioning data setting example
The following table shows the setting examples when "1-axis speed control (forward run: speed 1)" is set in the
positioning data No. 1 of axis 1.
Setting item
[Da.1]
[Da.2]
[Da.3]
[Da.4]
[Da.5]
Axis 1
positioning
data No. 1
[Da.6]
[Da.7]
[Da.8]
[Da.9]
[Da.10]
Refer to  Page 152, Section 5.3 for information on the setting details.
418
Setting example
Operation pattern
Positioning complete
Control system
Forward run speed 1
Acceleration time No.
Deceleration time No.
Axis to be interpolated
Positioning
address/movement
amount
Arc address
Command speed
6000.00mm/min
Dwell time
M code
Setting other than "Positioning complete" is not possible in speed
control.
Set 1-axis speed control.
Designate the value set in "[Pr.25] Acceleration time 1" as the
1
acceleration time at start.
Designate the value set in "[Pr.10] Deceleration time 0" as the
0
deceleration time at deceleration.
Setting not required. (Setting value will be ignored.)
Setting not required. (Setting value will be ignored.)
Setting not required. (Setting value will be ignored.)
Set the speed to be commanded.
Setting not required. (Setting value will be ignored.)
Set this when other sub operation commands are issued in combination
10
with the No. 1 positioning data. ("[Pr.18] M code ON signal output timing"
setting only possible in the WITH mode.)
Setting details

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-l ld75d

Table of Contents