(2) Positioning control
Stop cause
Drive unit READY signal
Forced stop
OFF
Hardware stroke limit
Fatal stop
upper/lower limit error
(Stop group 1)
occurrence
CPU module error
occurrence
Emergency stop
(Stop group 2)
PLC READY signal OFF
Error in test function
Axis error detection
Relatively safe stop
(Error other than stop
(Stop group 3)
group 1 or 2)
"Stop signal" ON from
external source
"Axis stop signal" ON
Intentional stop
from CPU module
(Stop group 3)
"Stop signal" from GX
*2
Works2
*1
When multiple positioning data is executed by the continuous positioning control and there is invalid setting value in a
positioning data, an error occurs and deceleration is performed at the previous positioning data. In this case, sudden
stop is not performed even when it is set for the stop group 3. If any of the following error occurs, the operation is
immediately stopped after executing up to previous positioning data of the positioning data where an error occurred.
• No command speed (error code: 503)
• Outside linear movement amount range (error code: 504)
• Large arc error deviation (error code: 506)
• Software stroke limit + (error code: 507)
• Software stroke limit - (error code: 508)
• Sub point setting error (error code: 525)
• End point setting error (error code: 526)
• Center point setting error (error code: 527)
• Outside radius range (error code: 544)
• Illegal setting of ABS direction in unit of degree (error code: 546)
*2
This means the stop using a stop button on the positioning test dialog box when using the positioning test function of GX
Works2.
40
M code ON
Stop axis
signal after stop
Each axis
No change
Each axis
No change
No change
All axes
Turns OFF
No change
Each axis
No change
*1
Each axis
No change
Axis operation
status ([Md.26])
Major positioning
after stopping
control
Error
Immediate stop
Deceleration stop/sudden stop
Error
(Select with "[Pr.37] Stop group 1 sudden stop
selection".)
Deceleration stop/sudden stop
Error
(Select with "[Pr.38] Stop group 2 sudden stop
selection".)
Error
Deceleration stop/sudden stop
(Select with "[Pr.39] Stop group 3 sudden stop
selection".)
Stopped
(Standby)
Stop process
High-level positioning
control