(16)[Cd.18] Continuous operation interrupt request
Item
• To interrupt a continuous operation, set "1" to this data item.
Setting details
• After processing the interruption request ("1"), the LD75 automatically resets the value to "0".
■Set with a decimal.
Setting
value
Setting value
Default value
0
Axis 1: 1520
Storage buffer memory
Axis 2: 1620
address
Axis 3: 1720
Axis 4: 1820
(17)[Cd.19] OPR request flag OFF request
Item
Setting details
The program can use this data item to forcibly turn the OPR request flag from ON to OFF.
■Set with a decimal.
Setting
value
Setting value
Default value
0
Axis 1: 1521
Storage buffer memory
Axis 2: 1621
address
Axis 3: 1721
Axis 4: 1821
222
K
1
Interruption request continuous operation
1: Interrupts continuous operation control
or continuous path control.
The LD75 resets the value to "0" automatically
when the continuous operation interrupt request is processed.
(This indicates the completion of continuous operation interruption request.)
K
1
OPR request flag OFF request
1: Turns the "OPR request flag"
from ON to OFF.
The LD75 resets the value to "0" automatically
when the OPR request flag is turned OFF.
(This indicates the completion of OPR request flag OFF request.)