List Of Devices Used - Mitsubishi Electric MELSEC-L LD75P User Manual

Positioning module
Hide thumbs Also See for MELSEC-L LD75P:
Table of Contents

Advertisement

6.2

List of Devices Used

In the program examples shown in this chapter and subsequent, the application of the devices used are as follows.
(1) When using the LD75 in a standard system configuration
(a) Inputs/outputs, external inputs/external outputs, and internal relays of LD75
Device name
Axis 1
X4
Input
X8
XC
X10
Inputs/outputs
of LD75
X14
Y4
Out-put
Y8
Y9
Y10
Device
Axis 2
Axis 3
Axis 4
X0
LD75 READY signal
X1
Synchronization flag
X5
X6
X7
M code ON signal
X9
XA
XB
Error detection signal
XD
XE
XF
BUSY signal
X11
X12
X13
Start complete signal
X15
X16
X17
Positioning complete signal
Y0
PLC READY signal
Y5
Y6
Y7
Axis stop signal
YA
YC
YE
Forward run JOG start signal
YB
YD
YF
Reverse run JOG start signal
Y11
Y12
Y13
Positioning start signal
CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL
Application
Preparation completed
LD75 buffer memory accessible
M code outputting
Error detected
BUSY (operating)
Start completed
Positioning completed
CPU module preparation completed
Requesting stop
Starting forward run JOG
Starting reverse run JOG
Requesting start
Details when ON
6
239

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-l ld75d