Positioning option enable/disable parameter setting program
(The program is not required when positioning option is not used.)
No. 2 Positioning data setting program
(For using positioning option)
(For positioning data No. 1 <axis 1>)
<Positioning identifier>
Operation pattern: Positioning complete
Control system: 1-axis linear control (ABS)
Acceleration time No.: 1, deceleration time No.: 2
<Positioning option>
M code ON signal output timing: WITH mode (1)
ABS direction in degrees: 0
Interpolation speed designation method: 0
CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL
Positioning option enable setting
Setting of positioning identifier
Setting of M code (9843)
Setting of dwell time (300ms)
Setting of positioning option
Setting of command speed
(180.00mm/min)
Setting of positioning address
(412.6μm)
Setting of arc address (0.0μm)
Setting of positioning data No. 1 to the
LD75