(d) Changing the speed ( Page 131, Section 5.2.3 (9))
The two modes for changing the speed are shown below.
• Standard switching  Switch the speed when executing the next positioning data.
• Front-loading switching  The speed switches at the end of the positioning data currently being executed.
[Standard speed switching mode]
• If the respective command speeds differ in the "positioning data currently being executed" and the
"positioning data to carry out the next operation", the machine will accelerate or decelerate after reaching
the positioning point set in the "positioning data currently being executed" and the speed will change over
to the speed set in the "positioning data to carry out the next operation".
• The parameters used in acceleration/deceleration to the command speed set in the "positioning data to
carry out the next operation" are those of the positioning data to carry out acceleration/deceleration. Speed
switching will not be carried out if the command speeds are the same.
Da. 1 O
Positioning start signal
[Y10, Y11, Y12, Y13]
Start complete signal
[X10, X11, X12, X13]
BUSY signal
Positioning complete signal
[X14, X15, X16, X17]
• Speed switching condition
If the movement amount is small in regard to the target speed, the current speed may not reach the target
speed even if acceleration/deceleration is carried out. In this case, the machine is
accelerated/decelerated so that it nears the target speed.
If the movement amount will be exceeded when automatic deceleration is required (Ex. Operation
patterns "00", "01"), the machine will immediately stop at the designated positioning address, and a
warning "Insufficient movement distance" (warning code: 513) will occur.
When the speed cannot be changed over in P2
When the relation of the speeds is P1 = P4, P2 = P3, P1 < P2.
P1
P2
350
Speed
V
switching
Positioning
peration pattern
11
ON
OFF
ON
OFF
ON
[XC, XD, XE, XF]
OFF
OFF
P3
P4
Dwell time
11
11
01
ON
When the movement amount is small during automatic deceleration
The movement amount required to carry out the automatic deceleration cannot
be secured, so the machine immediately stops in a speed  0 status.
Pn
Dwell time
t
00
Pn+1
Positioning address