(15)[Md.34] Movement amount after near-point dog ON
Item
• "0" is stored when machine OPR starts.
• After machine OPR starts, the movement amount from the near-point dog ON to the machine OPR completion is stored.
Storage details
(Movement amount: Movement amount to machine OPR completion using near-point dog ON as "0".)
• "0" is always stored when using the stopper method 1), 2), or 3).
■Monitoring is carried out with a hexadecimal display.
(High-order buffer memory) (Low-order buffer memory)
Reading the monitor
value
Actual value
Default value
0000H
Axis 1: 824, 825
Storage buffer memory
Axis 2: 924, 925
address
Axis 3: 1024, 1025
Axis 4: 1124, 1125
204
Monitor
E
F
G
H
value
A
B
C
D
Sorting
A
B
C
D
E
F
Converted from
hexadecimal to decimal
Decimal integer
R
value
Unit conversion
R
Target speed
Md.33
Md.34
Movement amount after
near-point dog ON
Description
Low-order buffer memory Example) 820
b15
b12
b8
E
F
High-order buffer memory Example) 821
b31
b28
b24
A
B
G
H
Unit conversion table
Md.33
Unit conversion table
n
10
Md.34
b4
b0
G
H
b20
b16
C
D
)
n
Unit
-2
mm/min
-3
inch/min
-3
degree/min
0
pulse/s
)
n
Unit
-1
m
inch
-5
degree
-5
pulse
0