7A-20 Heater and Ventilation:
3) Set air flow selector of HVAC control module to DEF
position with ignition switch ON, and make sure if the
position of actuator lever is DEF position (A).
4) Turn ignition switch OFF, and then disconnect
connector from air flow control actuator.
5) Measure resistance between terminal "1" and "3".
Air flow control actuator resistance between
terminal "1" and "3" (DEF position)
Approximately 4.9 kΩ
A
4
5
3
2
1
6) Connect connector to air flow control actuator.
7) Set air flow selector of HVAC control module to
VENT position with ignition switch ON, and make
sure if the position of actuator lever is VENT position
(B).
8) Turn ignition switch OFF, and then disconnect
connector from air flow control actuator.
9) Measure resistance between terminal "1" and "3".
Air flow control actuator resistance between
terminal "1" and "3" (VENT position)
Approximately 1.0 kΩ
B
4
5
3
2
1
If check result is not satisfactory, replace the actuator
with new one.

Actuator Linkage Inspection

• Check if each actuator linkage operates smoothly.
• Check actuator rod for bend.
• Check each actuator linkage for breakage.
• Make sure if there is not any obstruction in operating
range of actuator linkage.
If any malfunction is found, repair or replace faulty
part(s).
Center Ventilation Louver Removal and
Installation
Removal
1) Remove instrument panel center garnish referring to
2) Remove center ventilation louver (1) from instrument
5 4 3
2
1
I3RH0A710025-01
Installation
Reverse removal procedure to install center ventilation
louver.
5 4 3
2
1
I3RH0A710026-01
"HVAC Control Module Removal and Installation".
panel center garnish (2).
1
S3RH0A7106020
S3RH0A7106014
2
I3RH0A710017-01