Suzuki Liana RH413 Service Manual page 613

Table of Contents

Advertisement

Step
3
Check timing solenoid valve resistance
1) Turn ignition switch OFF.
2) Disconnect valve body harness connector (1, 2) on
transaxle.
3) Check for proper connection to solenoid valve at "GRN/
YEL" circuit.
4) Check resistance of solenoid valve.
4
5
10
9
Timing solenoid valve resistance
Between terminal of transaxle side valve body
harness connector and transaxle: 11 – 15 Ω at 20 °C
(68 °F)
Is check result satisfactory?
4
Check timing solenoid valve circuit for ground short
1) Connect valve body harness connector.
2) Disconnect TCM connectors.
3) Measure resistance between terminal "G08-10" of
disconnected harness side TCM connector and ground.
Is it 11 – 15
at 20
Action
2
3
2
1
8
7
6
°
°
C (68
F)?
Automatic Transmission/Transaxle:
Go to Step 4.
1
I2RH0B510029-01
Intermittent trouble or
faulty TCM.
Check for intermittent
referring to "Intermittent
and Poor Connection
Inspection in Section
00".
If OK, substitute a
known-good TCM and
recheck.
Yes
Replace timing solenoid
valve or lead wire.
"GRN/YEL" circuit
shorted to ground.
5A-65
No

Advertisement

Table of Contents
loading

This manual is also suitable for:

Liana rh416