Dtc B1513 (No.13): Temperature Control Actuator And/Or Its Circuit Malfunction - Suzuki Liana RH413 Service Manual

Table of Contents

Advertisement

Step
3
1) Check resistance between "RED/WHT" wire terminal
and body ground.
Is resistance more than 1 M
4
1) With ignition switch ON position, check voltage between
"RED/WHT" wire terminal and "BLK/RED" wire terminal
at air flow control actuator connector.
Is voltage about 5 V?
5
1) With ignition switch ON position, check voltage between
"WHT/BLU" wire terminal and "BLK/RED" wire terminal
at air flow control actuator connector.
Is voltage about 5 V?
6
1) Turn ignition switch OFF, disconnect HVAC control
module connector referring to "HVAC Control Module
Removal and Installation in Section 7A".
2) Check resistance between "WHT/BLU" wire terminal at
air flow control actuator connector and "WHT/BLU" wire
terminal at HVAC control module connector.
Is resistance less than 1 M
7
1) Check resistance between "WHT/BLU" wire terminal and
body ground.
Is resistance more than 1 M
8
1) Check air flow control actuator referring to "Air Flow
Control Actuator Inspection in Section 7A".
Is air flow control actuator normal?

DTC B1513 (No.13): Temperature Control Actuator and/or its Circuit malfunction

Wiring Diagram
2
M
1. HVAC control module
Action
?
?
?
G77-19
GRY/BLU
GRY
G77-20
5V
RED/WHT
G77-26
5V
WHT
G77-28
BLK/RED
G77-9
2. Temperature control actuator
Air Conditioning System: Automatic Type 7B-62
Poor connection of
"RED/WHT" wire
terminal at HVAC
control module
connector, and/or HVAC
control module faulty.
Go to Step 5.
Go to Step 8.
Go to Step 7.
Poor connection of
"WHT" wire terminal at
HVAC control module
connector, and/or HVAC
control module faulty.
HVAC control module
faulty.
1
12V
28
26
3. HVAC control module connector "G77" (viewed from harness side)
Yes
"RED/WHT" wire
shorted to ground.
"BLK/RED" wire open,
poor connection of
"BLK/RED" wire
terminal at HVAC
control module
connector, and/or HVAC
control module faulty.
Go to Step 6.
"WHT" wire open or
high resistance.
"WHT/BLU" wire
shorted to ground.
Air flow control actuator
faulty.
3
9
20 19
No
S3RH0A7224018
I3RH0A722015-01