Suzuki Liana RH413 Service Manual page 903

Table of Contents

Advertisement

Step
6
1) Turn ignition switch OFF, and then disconnect HVAC
control module connector referring to "HVAC Control
Module Removal and Installation in Section 7A".
2) Check resistance between "GRY" wire terminal and
body ground.
Is resistance more than 1 M
Temperature control actuator position sensor circuit inspection
Step
1
1) Turn ignition switch OFF, and then disconnect
temperature control actuator referring to "Temperature
Control Actuator Removal and Installation in Section
7A".
2) Turn ignition switch ON, and then check voltage
between "RED/WHT" wire terminal at temperature
control actuator connector and body ground.
Is voltage about 5 V?
2
1) Turn ignition switch OFF, and then disconnect HVAC
control module connector referring to "HVAC Control
Module Removal and Installation in Section 7A".
2) Check resistance between "RED/WHT" wire terminal at
temperature control actuator connector and "RED/WHT"
wire terminal at HVAC control module connector.
Is resistance less than 1 M
3
1) With ignition switch ON position and HVAC control
module connector connected, check voltage between
"RED/WHT" wire terminal and "BLK/RED" wire terminal
at temperature control actuator connector.
Is voltage about 5 V?
4
1) With ignition switch ON position, check voltage between
"WHT" wire terminal and "BLK/RED" wire terminal at
temperature control actuator connector.
Is voltage about 2.5 V?
5
1) Turn ignition switch OFF, disconnect HVAC control
module connector.
2) Check resistance between "WHT" wire terminal at
temperature control actuator connector and "WHT" wire
terminal at HVAC control module connector.
Is resistance less than 1 M
6
1) Check temperature control actuator referring to
"Temperature Control Actuator Inspection in Section 7A".
Is temperature control actuator normal?
Action
?
Action
?
?
Air Conditioning System: Automatic Type 7B-64
Yes
Poor connection of
"GRY" wire terminal at
HVAC control module
connector, and/or HVAC
control module faulty.
Yes
Go to Step 3.
Go to Step 3.
Go to Step 4.
Go to Step 6.
Go to Step 6.
HVAC control module
faulty.
No
"GRY" wire shorted to
ground.
No
Go to Step 2.
"RED/WHT" wire open
or high resistance, poor
connection of "RED/
WHT" wire terminal at
HVAC control module
connector, and/or HVAC
control module faulty.
"BLK/RED" wire open or
high resistance, poor
connection of "BLK/
RED" wire terminal at
HVAC control module
connector, and/or HVAC
control module faulty.
Go to Step 5.
"WHT" wire open or
high resistance, poor
connection of "WHT"
wire terminal at HVAC
control module
connector, and/or HVAC
control module faulty.
Temperature control
actuator faulty.

Advertisement