Diagnostic Information And Procedures - Suzuki Liana RH413 Service Manual

Table of Contents

Advertisement

Immobilizer Control System Check
Vehicle Not Equipped with Immobilizer Indicator Lamp
Step
1
1) Make sure that diagnosis switch terminal (2) in diagnosis
connector (color: blue) (3) is not grounded to ground
terminal (4) by service wire (1).
2) Check malfunction indicator lamp (1) while ignition
switch is ON (but without starting engine).
Does malfunction indicator lamp flash?
2
1) Using service wire (1), ground diagnostic switch terminal
(2) to ground terminal (4) in diagnosis connector (3).
Does malfunction indicator lamp flash?
3
Does malfunction indicator lamp flash ON and OFF at 0.5
sec. intervals?
4
1) Check DTC stored in Immobilizer Control Module
referring to "DTC Check".
Is there any DTC(s)?

Diagnostic Information and Procedures

Action
2
4
3
1
1
2
4
3
1
Immobilizer Control System:
Yes
Go to Step 3.
I3RH0AA30010-01
I3RH0AA30029-01
Immobilizer control
system is in good
condition.
I3RH0AA30010-01
Go to Step 4.
Go to flow or DTC No.
10C-6
S3RH0AA304001
No
If malfunction indicator
lamp remains ON, go to
Step 2.
If malfunction indicator
lamp remains OFF, go
to "Malfunction Indicator
Lamp (MIL) Check in
Section 1A".
Go to "Malfunction
Indicator Lamp (MIL)
Check in Section 1A".
Go to "Malfunction
Indicator Lamp (MIL)
Check in Section 1A".
Go to Step 5.