[E480] Bridge unit open jam
Classification
Cover open jam
Check item
Bridge unit cover opening/
closing detection sensor
LGC board
Parts to be replaced
Bridge unit cover opening/
closing detection sensor
LGC board
[E490] Job separator cover has opened during printing
Classification
Cover open jam
Check item
Job separator cover switch
LGC board
Parts to be replaced
Job separator cover switch
LGC board
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
Bridge unit open jam
Is the sensor working?
(Perform the input check: 03-[ALL]OFF/[7]/[B])
Connector check (J805)
Harness check
Board check
Connector check (CN354)
Harness check
Job separator cover open jam
Is the Job separator cover switch working?
(Perform the input check: 03-[ALL]OFF[7]/[B])
Connector check (CN260, CN261)
Harness check
Board check
Connector check (CN302)
Harness check