[E480] Bridge unit open jam
Classification
Cover open jam
Check item
Bridge unit cover opening/
closing detection sensor
LGC board
Parts to be replaced
Bridge unit cover opening/
closing detection sensor
LGC board
[E490] Job separator cover has opened during printing
Classification
Cover open jam
Check item
Job separator cover switch
LGC board
Parts to be replaced
Job separator cover switch
LGC board
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
Bridge unit open jam
•
Is the sensor working?
(Perform the input check: 03-[ALL]OFF/[7]/[B])
•
Connector check (J805)
•
Harness check
•
Board check
•
Connector check (CN354)
•
Harness check
Job separator cover open jam
•
Is the Job separator cover switch working?
(Perform the input check: 03-[ALL]OFF[7]/[B])
•
Connector check (CN260, CN261)
•
Harness check
•
Board check
•
Connector check (CN302)
•
Harness check
8 - 71
Error content
Measures
Remark
Error content
Measures
Remark
e-STUDIO2555C/3055C/3555C/4555C/5055C
ERROR CODE AND TROUBLESHOOTING
8