Step
Check Item
27
< Checking with the enforced
image position adjustment >
Does the error [CA00] occur during
the position adjustment control?
1. Turn the power ON while [0]
28
and [5] are pressed
simultaneously.
2. Key in "4719", then press the
[START] button. (05-4719:
Enforced position adjustment)
< Validating the color registration
control >
29
<Checking the image position
30
aligning sensor>
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
Result
Measure
Check if the photoconductive drum
and the transfer belt are rotating. If
not, correct their mechanism.
Check if there are abnormal stain,
large breaking or scratches on the
transfer belt surface.
Check if the connector of the
transfer transformer is
disconnected.
Check if the high-voltage harnesses
of the main high-voltage
transformer and the transfer
transformer are disconnected.
Check if the harness between the
LGC board and the transfer
transformer is broken.
Check if the high-voltage joints of
the transfer belt unit are securely
contacted or if they are not stained.
Check if the high-voltage harness is
broken.
Check if the connector of the main
high-voltage transformer is
disconnected.
Check if the harness between the
LGC board and the main high-
voltage transformer is broken.
Replace the transfer transformer.
Replace the main high-voltage
transformer.
Yes
No
Check the operation and correct if
necessary. Then be sure to perform
the following:
1. Turn the power ON while [0] and [8]
are pressed simultaneously.
2. Key in "4546", then press the
[START] button. (08-4546: Position
adjustment control / Mode setting)
3. Set the value to "4" (default value).
4. Turn the power OFF.
Clean the image position aligning
sensor (S7, S8).
e-STUDIO2555C/3055C/3555C/4555C/5055C
8 - 189
Next
Step
16
29
9